Patlak Parametric Image Estimation from Dynamic PET Using Diffusion Model Prior

Summary

This paper introduces a novel diffusion model-based kinetic modeling framework designed to improve the quality of parametric images estimated from dynamic PET, using the Patlak model as a specific example. By leveraging a pre-trained diffusion model's score function as a prior and incorporating kinetic model constraints, the framework successfully addresses issues of low image quality and ill-posedness in dynamic PET, demonstrating promising performance in total-body PET datasets.

Medical Relevance

This research is highly relevant to medicine by enabling more accurate and reliable quantitative estimation of physiological parameters from dynamic PET scans. Improved image quality from this framework can lead to better diagnostic accuracy, more precise disease monitoring, and enhanced treatment response assessment in various clinical applications.

AI Health Application

The research applies a 'diffusion model-based kinetic modeling framework' (a type of generative AI/machine learning) to enhance the quality of parametric images derived from dynamic PET scans. This constitutes an AI application to improve medical image processing and reconstruction, aiming for more accurate and reliable quantitative assessment of physiological parameters for clinical diagnosis and research.

Key Points

  • Addresses the challenge of low image quality in dynamic PET parametric imaging, stemming from ill-posed kinetic model fitting and limited counts, particularly in whole-body PET scans.
  • Proposes a novel diffusion model-based kinetic modeling framework for robust and high-quality estimation of physiological parameters.
  • Utilizes the Patlak model as a concrete example, estimating both slope and intercept images.
  • Employs a diffusion model whose score function is pre-trained on static total-body PET images, serving as a powerful prior for the Patlak parametric images by exploiting their patch-wise similarities.
  • Integrates the specific kinetic model (e.g., Patlak model) as a data-consistency constraint during the inference phase, guiding the parametric image estimation.
  • The framework was evaluated on total-body dynamic PET datasets with varying dose levels, demonstrating its feasibility and effectiveness in enhancing image quality.
  • The proposed method offers a significant improvement in quantitative physiological parameter estimation, crucial for research and clinical adoption of dynamic PET.

Methodology

The proposed methodology involves a diffusion model-based kinetic modeling framework. The core innovation is pre-training the score function of a diffusion model using static total-body PET images. This pre-trained score function then acts as a strong prior for the Patlak slope and intercept parametric images during inference, leveraging patch-wise similarities. Crucially, the kinetic model (Patlak in this case) is integrated as a data-consistency constraint to guide the estimation process. The framework was evaluated using total-body dynamic PET datasets, considering different dose levels.

Key Findings

The study demonstrated the feasibility and promising performance of the diffusion model-based kinetic modeling framework. It successfully improved the quality of parametric images estimated from dynamic PET data, even under challenging conditions such as limited counts or non-continuous acquisition, which are common in whole-body PET.

Clinical Impact

This framework has the potential to significantly enhance the clinical utility of dynamic PET by providing higher-quality and more reliable quantitative parametric maps. This could lead to more confident diagnoses, improved staging of diseases, better assessment of treatment efficacy, and facilitate more robust physiological research, especially with the growing adoption of total-body PET scanners where data scarcity can be an issue.

Limitations

The abstract does not explicitly state specific limitations of the proposed framework. However, the phrases "feasibility and promising performance" often imply that it is an initial validation, suggesting further extensive testing and validation across diverse clinical scenarios and patient populations would be beneficial.

Future Directions

Future research directions are not explicitly mentioned in the provided abstract.

Medical Domains

Nuclear Medicine Medical Imaging Radiology Oncology Neurology Cardiology

Keywords

Dynamic PET Parametric Imaging Patlak Model Diffusion Model Kinetic Modeling Total-body PET Image Quality Physiological Parameters

Abstract

Dynamic PET enables the quantitative estimation of physiology-related parameters and is widely utilized in research and increasingly adopted in clinical settings. Parametric imaging in dynamic PET requires kinetic modeling to estimate voxel-wise physiological parameters based on specific kinetic models. However, parametric images estimated through kinetic model fitting often suffer from low image quality due to the inherently ill-posed nature of the fitting process and the limited counts resulting from non-continuous data acquisition across multiple bed positions in whole-body PET. In this work, we proposed a diffusion model-based kinetic modeling framework for parametric image estimation, using the Patlak model as an example. The score function of the diffusion model was pre-trained on static total-body PET images and served as a prior for both Patlak slope and intercept images by leveraging their patch-wise similarity. During inference, the kinetic model was incorporated as a data-consistency constraint to guide the parametric image estimation. The proposed framework was evaluated on total-body dynamic PET datasets with different dose levels, demonstrating the feasibility and promising performance of the proposed framework in improving parametric image quality.

Comments

10 pages, 9 figures