Graph Deep Learning for Intracranial Aneurysm Blood Flow Simulation and Risk Assessment

Summary

This paper introduces a novel graph neural network (GNN) surrogate model designed to rapidly and accurately simulate blood flow hemodynamics in intracranial aneurysms. By processing vascular geometries, the model predicts critical rupture risk indicators like wall shear stress and oscillatory shear index within minutes, overcoming the speed and resolution limitations of conventional CFD simulations and 4D Flow MRI. This approach aims to provide real-time, high-resolution hemodynamic analysis, transforming complex simulations into an accessible clinical decision support tool.

Medical Relevance

This research significantly advances the ability to precisely and rapidly assess intracranial aneurysm rupture risk, providing clinicians with crucial, high-resolution hemodynamic data. This allows for more timely, personalized, and informed clinical decision-making regarding patient risk stratification, treatment planning, and management strategies.

AI Health Application

The research develops an AI-powered (graph neural network) decision support system for accelerated and high-resolution intracranial aneurysm blood flow simulation and rupture risk assessment. This system integrates with existing patient imaging pipelines to provide near real-time, clinically interpretable hemodynamic predictions, enhancing current hospital assessment methods and enabling 'bedside aneurysm analysis' without specialized computational expertise.

Key Points

  • Addresses the critical need for rapid and high-resolution hemodynamic assessment in intracranial aneurysms, crucial for understanding rupture risk tied to wall shear stress (WSS) and oscillatory shear index (OSI).
  • Proposes a graph neural network (GNN) surrogate model that generates full-field hemodynamics directly from vascular geometries.
  • The model is trained on a comprehensive dataset of high-fidelity computational fluid dynamics (CFD) simulations of patient-specific aneurysms.
  • Its architecture combines graph transformers for spatial feature learning with autoregressive predictions for temporal evolution, accurately simulating blood flow, WSS, and OSI.
  • Achieves significant acceleration, reproducing hemodynamics in less than one minute per cardiac cycle, vastly outperforming conventional CFD's prohibitive slowness.
  • Demonstrates robust generalization capabilities across unseen patient geometries and inflow conditions without requiring mesh-specific calibration.
  • Enables near real-time, high-resolution hemodynamic predictions that can be integrated with existing clinical imaging pipelines, making advanced analysis accessible without specialized computational expertise.

Methodology

The study develops a graph neural network (GNN) surrogate model. This model is trained using a comprehensive dataset derived from high-fidelity computational fluid dynamics (CFD) simulations of patient-specific intracranial aneurysms. The GNN architecture integrates graph transformers for effective learning of spatial relationships within vascular geometries and employs autoregressive predictions to capture temporal blood flow dynamics, thereby simulating full-field hemodynamics.

Key Findings

The GNN model accurately reproduces high-fidelity full-field hemodynamics, including blood flow, wall shear stress (WSS), and oscillatory shear index (OSI). It achieves this at an unprecedented speed, completing simulations in less than one minute per cardiac cycle. Furthermore, the model exhibits strong generalization, performing well on unseen patient geometries and inflow conditions without requiring mesh-specific calibration.

Clinical Impact

This work transforms high-fidelity hemodynamic simulations from an expert-only research tool into a deployable, data-driven decision support system readily usable by clinicians. It enables near real-time, high-resolution aneurysm analysis at the bedside, integrated with existing imaging pipelines, fostering direct comparison with current clinical assessments. This advancement promises to improve the efficiency and accuracy of intracranial aneurysm risk assessment and management, without requiring computational specialists.

Limitations

The abstract does not explicitly state limitations. However, potential limitations for such models typically include dependence on the quality and diversity of the training data (high-fidelity CFD simulations), potential challenges in accurately modeling extremely rare or complex aneurysm morphologies not represented in the training set, and the need for rigorous prospective clinical validation against *in-vivo* measurements.

Future Directions

The authors suggest that this framework establishes the foundation for clinically interpretable hemodynamic prediction, indicating future work on model interpretability and deeper integration into clinical decision-making processes. The ultimate goal of achieving "real-time, bedside aneurysm analysis" implies continued development towards widespread clinical deployment and validation across diverse patient cohorts.

Medical Domains

Neurosurgery Neuroradiology Medical Imaging Computational Medicine Vascular Surgery

Keywords

Intracranial Aneurysm Hemodynamics Graph Neural Network Wall Shear Stress Oscillatory Shear Index Computational Fluid Dynamics Risk Assessment Machine Learning

Abstract

Intracranial aneurysms remain a major cause of neurological morbidity and mortality worldwide, where rupture risk is tightly coupled to local hemodynamics particularly wall shear stress and oscillatory shear index. Conventional computational fluid dynamics simulations provide accurate insights but are prohibitively slow and require specialized expertise. Clinical imaging alternatives such as 4D Flow MRI offer direct in-vivo measurements, yet their spatial resolution remains insufficient to capture the fine-scale shear patterns that drive endothelial remodeling and rupture risk while being extremely impractical and expensive. We present a graph neural network surrogate model that bridges this gap by reproducing full-field hemodynamics directly from vascular geometries in less than one minute per cardiac cycle. Trained on a comprehensive dataset of high-fidelity simulations of patient-specific aneurysms, our architecture combines graph transformers with autoregressive predictions to accurately simulate blood flow, wall shear stress, and oscillatory shear index. The model generalizes across unseen patient geometries and inflow conditions without mesh-specific calibration. Beyond accelerating simulation, our framework establishes the foundation for clinically interpretable hemodynamic prediction. By enabling near real-time inference integrated with existing imaging pipelines, it allows direct comparison with hospital phase-diagram assessments and extends them with physically grounded, high-resolution flow fields. This work transforms high-fidelity simulations from an expert-only research tool into a deployable, data-driven decision support system. Our full pipeline delivers high-resolution hemodynamic predictions within minutes of patient imaging, without requiring computational specialists, marking a step-change toward real-time, bedside aneurysm analysis.